PT67-21B/C14/TR8)
Reliability Test Item And Condition
The reliability of products shall be satisfied with items listed below.
Confidence level : 90%
LTPD : 10%
NO. Item
Test Conditions
Test Hours/ Sample
Cycles
Sizes
Failure
Judgement
Ac/Re
Criteria
1 REFLOW
TEMP. : 260 ℃± 5 ℃
6Mins
22pcs
0/1
5secs
2 Temperature Cycle H : 100 ℃
L : -40 ℃
15mins 50Cycles
5mins
15mins
22pcs
I C(ON) ≦ L × 0.8
0/1
3 Thermal Shock
H :+100 ℃
5mins 50Cycles
22pcs
L : Lower
0/1
10secs
Specification
L :-10 ℃
5mins
Limit
4 High Temperature
TEMP. : +100 ℃
1000hrs
22pcs
0/1
Storage
5 Low Temperature
TEMP. : -40 ℃
1000hrs
22pcs
0/1
Storage
6 DC Operating Life V CE =5V
7 High Temperature/ 85 ℃ / 85% R.H
1000hrs
1000hrs
22pcs
22pcs
0/1
0/1
High Humidity
Everlight Electronics Co., Ltd.
http:\\www.everlight.com
Rev 1
Page: 8 of 10
Device No : DTT-067-248
Prepared date : 10-27-2006
Prepared by : JAINETSAI